BLTouch::z_extra_clearance() use probe offset instead of full travel #25655
BLTouch::z_extra_clearance() use probe offset instead of full travel #25655
Conversation
b1e87b8
to
4aa3ff2
Compare
Using the full probe stroke defeats some of the speed advantage for using high speed mode, only use full probe stroke if the nozzle offset isn't available.
4aa3ff2
to
9e273aa
Compare
07baf9b
to
4376091
Compare
The reason we avoid using Meanwhile, I have been thinking of moving the "extra probe offset" to the |
I've warmed up to this idea, but I'm choosing to set the default to a very conservative value. Users may choose to change it for their own setups, and we can certainly pick better defaults for existing example configurations. As always, our main concern is not to break anyone's probes, so I think this is a good compromise. |
Another thing occurs to me in the moment: We could make 7 the maximum value that gets returned by |
cb3d77a
to
08069a6
Compare
I have reviewed these changes and they look good to me. |
For now I think it's fine to keep it specific to the BLTouch. I'm running through There are one or two other things I'd like to adjust, but those can wait. Specifically, when homing XY for the first time, with Z being unknown, there is an initial raise to ensure clearance. Then before the probe deploys for Z-homing there is another raise because Z is still not considered to be known. Since there was already one raise, if that raise was sufficient, it would be nice to be able to skip that second raise for probe deployment. I'm contemplating a clean way to handle that, without setting the "Z known" flag, since that flag is still useful. What I might do is set it "known" just before attempting Z homing, if the previous raise was done, and just always set it to "unknown" if Z homing fails. We'll see how that goes…. |
Here's my branch with all my bed probing related changes. The parts you've seen are out of date relative to your changes. I'm not making a pull request for the whole yet, because the later ones still need work, I just thought I'd push up my work and give an overview of my pain points and where I had been going with the changes I was submitting. Pain points of making up for a bad printer hardware design delivering 3.3V to a 5V BLTouch (probe_at_point detecting and retrying bad probes), using G30 to measure the height of a reasonably tall model to resume, I had problems from the start with the BLTouch triggering early, not every 5x5 auto bed level, but I couldn't trust it. The "adaptive probing" helped by probing twice, comparing the value, if it was out of tolerance of 0.03mm, I would have it keep probing until it either got consistent numbers or if reached a limit and threw a firmware failure. I'm also using OctoPrint with a custom plugin to check the auto bed level numbers, and abort the job if any is 0.1 mm or greater from the average. This has also been useful when detecting if I forgot to clear the previous model (if it is small enough). Creality Ender 6 has a breakout board that the BLTouch is connected to, that board was giving it 3.3V, connecting the BLTouch directly to the main board with a longer shielded cable has resolved the triggered early while the probe was vary far away from the board, I'll still see repeated probes at a point, but it is much better. I see other probe and compare algorithms will probe a fixed number of times, compare, if they are good go on, if they aren't close enough, it starts over at that location. I'm considering going to that algorithm, it should simplify the logic. It is possible that the current algorithm throws away the wrong value if enough bad values align and it fails when it shouldn't. I wrote it when I my bad values were way off. That's probably not typical. The other theme of my changes is in recovering a failed print. Then there was finding my 5x5 auto bed probe time dramatically increased from 2.0.9.3 to bugfix-2.1.x branch for me went from 3:19 to 4:34, and that's where the bltouch avoid sending the same deploy() or stow() came from you've merged. There's another change you haven't seen "Add a new Z_PROBE_FEEDRATE_RAISE", I'm assuming the fast rate and slow rate when probing down are less than the printer's maximum rate because a slower rate means more time to react to the probe trigger and more time to stop and get a better reading. That doesn't apply when moving away from the board, because it isn't probing and the planner will know ahead of time where to stop. The default maximum for my printer is 10mm/s for Z so that's what I'm using. You mentioned other ways of probing faster. Here's another one "Decrease the total time by moving Z at the same time as XY" I'm not really expecting that one to go in, but it does cut down the probe time. Currently when the last sample at a location is finished, Z goes all the way up, moves XY, then starts the next probe. With this change Z goes up enough to clear the build plate and a little more, then diagonally moves X/Y/Z to the next point. In this case most of the time for Z up is hidden in the XY movement. End result 2.0.9.3 3:19, bugfixes-2.1 + all changes 1:07, that's with 150mm/s XY, 10mm/s Z. |
* bugfix-2.1.x: (37 commits) 🚸 Minor M43 improvements 🐛 Fix BLTOUCH_HS_MODE config [cron] Bump distribution date (2023-04-12) 🚸 BLTouch extra clearance for PROBE_PT_RAISE 🚸 More clearance on fast probe failure 🧑💻 Use largest_sensorless_adj in DELTA run_z_probe 🧑💻 Update move_z_after_probing/homing 🧑💻 Modify try_to_probe sanity-checking 🧑💻 Clarify G28 R / R0 🧑💻 Probe flag in do_z_clearance 🧑💻 More debug in motion.* 📝 Improve G30 description ✨ BLTOUCH_HS_EXTRA_CLEARANCE (MarlinFirmware#25655) [cron] Bump distribution date (2023-04-11) 📝 Describe G34, spellcheck 🩹 Fix BLTouch stow in homeaxis(Z) 🚸 Fix G30 behavior 🎨 Misc. probe-related cleanup [cron] Bump distribution date (2023-04-10) 🔧 Update thermocouple 2 pin sanity check (MarlinFirmware#25627) ... # Conflicts: # .github/workflows/bump-date.yml # Marlin/Configuration.h # Marlin/Configuration_adv.h
Not sure this PR is the cause but I got a G34 failure because now probe doesn't raise enough to let bltouch do a proper deploy. I try do step back and do a better check |
See #25631. It started out as a bunch of probe/homing fixes and is now just G34 fixes. Thinkyhead still needs to push some more changes before it's merged. |
@thisiskeithb yep, I think you got it. Description seems talking about my issue. Thanks |
Co-authored-by: Scott Lahteine <thinkyhead@users.noreply.github.com>
Co-authored-by: Scott Lahteine <thinkyhead@users.noreply.github.com>
Co-authored-by: Scott Lahteine <thinkyhead@users.noreply.github.com>
Co-authored-by: Scott Lahteine <thinkyhead@users.noreply.github.com>
Co-authored-by: Scott Lahteine <thinkyhead@users.noreply.github.com>
Description
Using the full probe stroke defeats some of the speed advantage for using high speed mode, only use full probe stroke if the nozzle offset isn't available.
Requirements
BLTouch
Benefits
I developed this while probe.cpp still used z_extra_clearance() , now that probe.cpp doesn't use it, this clearance will not be used nearly as often. Traveling the full stroke vs much less isn't going to have as much impact on a print job.