aileo
Copy link
Contributor

@aileo aileo commented Jun 22, 2020

This should replace #60 and #65 as they are both out of date.

It is just another attempt and is not meant to be merged as is.

Modifications:

  • Add autoParse boolean to PoweredUp which enable parsing from port mode information, disabled by default
  • Attach event is emitted when the device is "ready", meaning when it knows how to parse (immediately when auto parsing is disabled and when all modes are ok when auto parsing is enabled
  • devices receive method call super.receive when auto parsing
  • devices expose events get method to retrieve an array of available events, as it uses the mode names as events
  • devices expose setModes method to allow hubs to set modes configuration

Thought:

  • All port specific messages (except attach/detach) parsing may be deferred to the device class or at least mode ones.
  • I have to admit that it takes a while to get all modes on some sensors
  • using mode names for events is not nice, also values are provided as an Array to handle all cases (RGB...)
  • It needs some conversion from raw to SI

@aileo
Copy link
Contributor Author

aileo commented Jun 22, 2020

Just made a small test: removing ColorDistanceSensor class and using autoparse to control the device, it works.

I think the same kind of code could be done for output modes and auto parsing could be enabled by default for unknown devices.

@nathankellenicki
Copy link
Owner

Wow nice, quite a lot to unpack here. :) I'll have to give it a good test at the weekend at some point, but its definitely promising.

Perhaps if this makes it in I can modify my dev branch that implements combined sensor modes in.

Regarding the mode names - I agree, they're not suited to event handlers. Perhaps a mapping of mode names to events could be implemented so that we could keep the existing event names.

@aileo
Copy link
Contributor Author

aileo commented Jun 23, 2020

I added autoparseWriteDirect (bad naming) which will use output modes definitions to send data.

To test, I removed the TECHNIC_LARGE_LINEAR_MOTOR from basehub and I was able to control one with this:

hub.on("attach", (device) => {
    const outputs = device.writeModes
    if (outputs.includes('SPEED')) {
        device.autoparseWriteDirect('SPEED', [50])
    }
});

Now that I pushed, I notice that maybe I should define autoparseWriteDirect like this:

public autoparseWriteDirect (mode: string, ...data: number[])
// instead of
public autoparseWriteDirect (mode: string, data: number[])

So it does not need an array of values...

Wow nice, quite a lot to unpack here. :) I'll have to give it a good test at the weekend at some point, but its definitely promising.

Thank you, I hope it will be up to it.

Perhaps if this makes it in I can modify my dev branch that implements combined sensor modes in.

Cherry on the cake

Regarding the mode names - I agree, they're not suited to event handlers. Perhaps a mapping of mode names to events could be implemented so that we could keep the existing event names.

I think it is the best compromise, as it could also allow some special conversion (like distance).

Still in my TODO:

  • enable autoparse by default for unknown device
  • some JSON declaration to use the autoparse without port mode information messages

@aileo
Copy link
Contributor Author

aileo commented Jun 24, 2020

  • All port specific messages (except attach/detach) parsing may be deferred to the device class or at least mode ones.

@nathankellenicki , your thoughts on this ?

@@ -15,6 +15,10 @@ export class DuploTrainBaseSpeedometer extends Device {
}

public receive (message: Buffer) {
if (this.hub.autoParse) {
Copy link
Owner

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

These are quite repetitive, and error prone when new devices are added (ie. could forget to do this). Could the check be done at hub level, calling either receive or autoParse?

Copy link
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

I am thinking about another way to do this:

  1. Define all known modes like auto parsed ones and add them in the constructor.
  2. always use Device.receive to parse incoming messages (including mode information) and emit lego named events
  3. make the specific device classes to listen on their lego events to emit proper ones

No more receive method in specific device classes, just event handlers that could use private methods to handle mode calculation and formating.

Copy link
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

I totally forgot about the subscription logic in the comment above. It will need the correct mode map.

src/hubs/lpf2hub.ts Outdated Show resolved Hide resolved
@nathankellenicki
Copy link
Owner

Ok so I had some time to test this this afternoon, overall, it seems to work well. Great work :)

  • I like that this doesn't override any of the existing methods - I feel those are more user friendly than autoParsing. autoParsing seems like it would mainly be used as a fallback or for debugging a non-implemented device.

  • Saying that, I see the potential in the future to move methods such as setPower/rotateByAngle etc away from sending byte arrays, to writing values via mode names (ie. POWER/POS etc), meaning the modes wouldn't need to be hardcoded. To do this though we'd really need to make sure that mode names and values are consistent between all devices - I don't trust Lego. :D

I spotted a couple of bugs and inconsistencies.

  1. When using waitForDeviceByType after connect,, and the device is already plugged in at connection time, the promise is resolved, returning a device without any modes. Seems like this should wait for autoParsing to complete too?

  2. Some naming conventions I have/will comment on separately.

@nathankellenicki
Copy link
Owner

  • All port specific messages (except attach/detach) parsing may be deferred to the device class or at least mode ones.

@nathankellenicki , your thoughts on this ?

I'm not sure I follow what you mean here - message parsing is already deferred to the device class?

@nathankellenicki
Copy link
Owner

  • All port specific messages (except attach/detach) parsing may be deferred to the device class or at least mode ones.

@nathankellenicki , your thoughts on this ?

I'm not sure I follow what you mean here - message parsing is already deferred to the device class?

Actually I think I understand now, are you referring to _parseModeInformationResponse, and potentially moving it to the device class?

Yes, I think I agree with this. I found it somewhat jarring at first that setModes is called by the hub - it seems like something that should be handled by the device. But this becomes more appropriate if mode parsing is deferred to the device class.

return;
}
const { name, raw, pct, si, values } = this._modes[mode];
const valueSize = Consts.ValueTypeSize[values.type];
Copy link
Owner

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

I haven't checked on all devices, but do all device modes only accept one type of value? Even for multiple values?

Are there any instances where a device could have ie. 3x int32, 1x uint8? I don't know if the UART protocol even supports that.

Copy link
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

I would say they mix everything as in the boost color and distance sensor:

[
  {
    "name": "COLOR",
    "input": true,
    "output": false,
    "raw": { "min": 0, "max": 10 },
    "pct": { "min": 0, "max": 100 },
    "si": { "min": 0, "max": 10, "symbol": "IDX" },
    "values": {
      "count": 1,
      "type": 0
    }
  },
  {
    "name": "PROX",
    "input": true,
    "output": false,
    "raw": { "min": 0, "max": 10 },
    "pct": { "min": 0, "max": 100 },
    "si": { "min": 0, "max": 10, "symbol": "DIS" },
    "values": {
      "count": 1,
      "type": 0
    }
  },
  "[...]",
  {
    "name": "SPEC 1",
    "input": true,
    "output": false,
    "raw": { "min": 0, "max": 255 },
    "pct": { "min": 0, "max": 100 },
    "si": { "min": 0, "max": 255, "symbol": "N/A" },
    "values": {
      "count": 4,
      "type": 0
    }
  },
  "[...]"
]

For SPEC 1, which includes values from COLOR and PROX modes, it use 0-255 as range instead of 0-10 to match other values.

Copy link

@tthiery tthiery Jul 1, 2020

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

As an example, the tilt sensor of the TechnicMediumHub has different data types for different modes in use (Int8, Int32, Int16) but within one mode, the data type is always the same. At least, that is what the device/spec is self-declaring.

Port: 99
    IOTypeId: TechnicMediumHubTiltSensor
    HardwareRevision: 0.0.0.1
    SoftwareRevision: 0.0.0.1
    OutputCapability: True
    InputCapability: True
    LogicalCombinableCapability: True
    LogicalSynchronizableCapability: True
    ModeCombinations: []
    UsedCombinationIndex: 0
    MultiUpdateEnabled: False
    ConfiguredModeDataSetIndex: []
    Mode: 0
      Name: POS
      IsInput: True
      IsOutput: False
      RawMin: -180
      RawMax: 180
      PctMin: -100
      PctMax: 100
      SIMin: -180
      SIMax: 180
      Symbol: DEG
      InputSupportsNull: False
      InputSupportFunctionalMapping20: True
      InputAbsolute: True
      InputRelative: False
      InputDiscrete: False
      OutputSupportsNull: False
      OutputSupportFunctionalMapping20: False
      OutputAbsolute: False
      OutputRelative: False
      OutputDiscrete: False
      NumberOfDatasets: 3
      DatasetType: Int16
      TotalFigures: 3
      Decimals: 0
      DeltaInterval: 0
      NotificationEnabled: False
    Mode: 1
      Name: IMP
      IsInput: True
      IsOutput: False
      RawMin: 0
      RawMax: 100
      PctMin: 0
      PctMax: 100
      SIMin: 0
      SIMax: 100
      Symbol: CNT
      InputSupportsNull: False
      InputSupportFunctionalMapping20: False
      InputAbsolute: False
      InputRelative: True
      InputDiscrete: False
      OutputSupportsNull: False
      OutputSupportFunctionalMapping20: False
      OutputAbsolute: False
      OutputRelative: False
      OutputDiscrete: False
      NumberOfDatasets: 1
      DatasetType: Int32
      TotalFigures: 3
      Decimals: 0
      DeltaInterval: 0
      NotificationEnabled: False
    Mode: 2
      Name: CFG
      IsInput: False
      IsOutput: True
      RawMin: 0
      RawMax: 255
      PctMin: 0
      PctMax: 100
      SIMin: 0
      SIMax: 255
      Symbol:
      InputSupportsNull: False
      InputSupportFunctionalMapping20: False
      InputAbsolute: False
      InputRelative: False
      InputDiscrete: False
      OutputSupportsNull: False
      OutputSupportFunctionalMapping20: False
      OutputAbsolute: True
      OutputRelative: False
      OutputDiscrete: False
      NumberOfDatasets: 2
      DatasetType: SByte
      TotalFigures: 3
      Decimals: 0
      DeltaInterval: 0
      NotificationEnabled: False

@nathankellenicki
Copy link
Owner

I don't know what can be done about it, but I noticed that the emitted values for POS on Technic motors (and likely others) aren't consistent with the pct/si values they claim. For example:

This is the emitted POS values when setting power to 30:

{ raw: [ 0 ], pct: [ 0 ], si: [ 0 ] }
{ raw: [ 1 ], pct: [ 0.27777777777777146 ], si: [ 1 ] }
{ raw: [ 11 ], pct: [ 3.055555555555543 ], si: [ 10.999999999999943 ] }
{ raw: [ 27 ], pct: [ 7.5 ], si: [ 27 ] }
{ raw: [ 45 ], pct: [ 12.5 ], si: [ 45 ] }
{ raw: [ 62 ], pct: [ 17.22222222222223 ], si: [ 62 ] }
{ raw: [ 82 ], pct: [ 22.777777777777786 ], si: [ 82 ] }
{ raw: [ 99 ], pct: [ 27.499999999999986 ], si: [ 98.99999999999994 ] }
{ raw: [ 120 ], pct: [ 33.333333333333314 ], si: [ 120 ] }
{ raw: [ 141 ], pct: [ 39.16666666666666 ], si: [ 141 ] }
{ raw: [ 161 ], pct: [ 44.72222222222223 ], si: [ 161 ] }
{ raw: [ 181 ], pct: [ 50.27777777777777 ], si: [ 181 ] }
{ raw: [ 200 ], pct: [ 55.55555555555557 ], si: [ 200 ] }
{ raw: [ 219 ], pct: [ 60.83333333333334 ], si: [ 219 ] }
{ raw: [ 239 ], pct: [ 66.38888888888889 ], si: [ 239 ] }
{ raw: [ 257 ], pct: [ 71.38888888888889 ], si: [ 257 ] }
{ raw: [ 276 ], pct: [ 76.66666666666666 ], si: [ 276 ] }
{ raw: [ 295 ], pct: [ 81.94444444444443 ], si: [ 295 ] }
{ raw: [ 315 ], pct: [ 87.5 ], si: [ 315 ] }
{ raw: [ 334 ], pct: [ 92.77777777777777 ], si: [ 334 ] }
{ raw: [ 353 ], pct: [ 98.05555555555557 ], si: [ 353 ] }
{ raw: [ 373 ], pct: [ 100 ], si: [ 360 ] }
{ raw: [ 392 ], pct: [ 100 ], si: [ 360 ] }
{ raw: [ 411 ], pct: [ 100 ], si: [ 360 ] }
{ raw: [ 430 ], pct: [ 100 ], si: [ 360 ] }
{ raw: [ 450 ], pct: [ 100 ], si: [ 360 ] }
{ raw: [ 469 ], pct: [ 100 ], si: [ 360 ] }
{ raw: [ 491 ], pct: [ 100 ], si: [ 360 ] }
{ raw: [ 511 ], pct: [ 100 ], si: [ 360 ] }
{ raw: [ 531 ], pct: [ 100 ], si: [ 360 ] }

As you can see, they claim the max value is 360, and that 0-100% = 0-360, however I believe the values can actually go -2147483646-2147483647 due to the Int32.

Dammit Lego. >.<

@aileo
Copy link
Contributor Author

aileo commented Jun 28, 2020

  • All port specific messages (except attach/detach) parsing may be deferred to the device class or at least mode ones.

@nathankellenicki , your thoughts on this ?

I'm not sure I follow what you mean here - message parsing is already deferred to the device class?

Actually I think I understand now, are you referring to _parseModeInformationResponse, and potentially moving it to the device class?

Yes, I think I agree with this. I found it somewhat jarring at first that setModes is called by the hub - it seems like something that should be handled by the device. But this becomes more appropriate if mode parsing is deferred to the device class.

Exactly

@aileo
Copy link
Contributor Author

aileo commented Jun 28, 2020

As you can see, they claim the max value is 360, and that 0-100% = 0-360, however I believe the values can actually go -2147483646-2147483647 due to the Int32.

Is this case, maybe the code should use modulo instead of clamping... but there is no guarantee it would work for other metrics...

Dammit Lego. >.<

  • I don't trust Lego. :D

Consistency does not seem to be their first priority

Léo Bonnargent added 2 commits June 28, 2020 23:07
@aileo
Copy link
Contributor Author

aileo commented Jun 28, 2020

I think I almost broke everything with some improvments:

  • added mode definitions to each specific device class (I dont have duplo and spike ones so I made it up)
  • device classes have per mode specific functions to emit related event. If not, it emit the full raw+pct+si event using mode name.
  • devices are in charge of messages they are related to (except attach/detach):
    • port information
    • mode information
    • sensor message
    • port action
  • modeMap is built from mode definitions

Problems:

  • I dont think it is still compatible with the wedo2 but I dont think it is a lot of work to get it back:
    • All sensor parsing is done in Device.receive
    • mode definitions could have an optional flag to specify if mode is compatible with wedo2
    • autoParse may (should?) be disabled on wedo2
  • I wanted to export the mode definitions from each device file but the current and voltage sensor mode definitions are related to the hub type (max values). I wonder if this devices should be on autoParse by default like unknown? (Not so much modes and accuracy on future values)
  • Some mode definitions are missing, I dont have the related devices:
    • mode 0x01 on DuploTrainBaseColorSensor (I assume it would be count or ambient)
    • modes 0x02, 0x03 and 0x04 on TechnicDistanceSensor

As you can see, the "problems" part is bigger than the other one...

export const modes = TachoMotorModes.concat([
// POWER
// SPEED/speed
// POS/rotate
Copy link
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

It add mode to the existing ones in TachoMotor

* @param {number} absolute
*/
this.notify("absolute", { angle });
};
Copy link
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

add handle for rotate mode. Using raw instead of SI because we know it does not convert very well on angles

si: { min: -100, max: 100, symbol: "PCT" },
values: { count: 1, type: Consts.ValueType.Int8 }
}
];
Copy link
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

mode definitions are exported to be used by TachoMotor

protected _mode: number | undefined;
protected _modeMap: {[event: string]: number} = {};
Copy link
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

_modeMap is now protected so it can be used in device class to subscribe to mode

this._isWeDo2SmartHub = (this.hub.type === Consts.HubType.WEDO2_SMART_HUB);
this._isVirtualPort = this.hub.isPortVirtual(portId);

if (!this.autoParse) {
this._init();
}
Copy link
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

_init is call once device have all its mode definitions

this._modeMap = this._modes.reduce((map: {[name: string]: number}, mode, index) => {
map[mode.name] = index;
return map;
}, {});
Copy link
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

generate modeMap from mode definitions


if (mode === this._modeCount - 1) {
this._init();
}
Copy link
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Call init when we are done with mode information messages (and autoParse enabled)

pct: { min: 0, max: 100 },
si: { min: 0, max: 5120, symbol: "mm" },
values: { count: 1, type: Consts.ValueType.Int16 }
}
Copy link
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

mode definition handle the * 10 in SI max.

constructor (hub: IDeviceInterface, portId: number, modeMap: {[event: string]: number} = {}, type: Consts.DeviceType = Consts.DeviceType.TECHNIC_MEDIUM_ANGULAR_MOTOR) {
super(hub, portId, {}, type);
constructor (hub: IDeviceInterface, portId: number) {
super(hub, portId, [], Consts.DeviceType.TECHNIC_MEDIUM_ANGULAR_MOTOR);
Copy link
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Other similar motor are defined this way so I though it would be better as it is shorter

pct: {min: -100, max: 100},
si: {min: -2000, max: 2000, symbol: "DPS"},
values: {count: 3, type: Consts.ValueType.Int16}
}
Copy link
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

I dont understand how max of Int16 can be a decimal.

Copy link

@tthiery tthiery Jul 1, 2020

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

the system communicates int16. rawMin and rawMax are not the boundaries of this values but the scaling baseline on the SI/pct min/max. That is the same as for the motors. their pos is a fully utilized int32 but rawMin/rawMax are -360 to 360.

just do not think of them as min and max of the related communicated raw value. But as an input for the formula to calculate SI and PCT.

Copy link
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Oh, then I will remove the "clamping" logic of the normalize function.


if (device) {
device.receive(message);
}
Copy link
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

send all device messages to device

@aileo aileo marked this pull request as draft June 29, 2020 14:34
@tthiery
Copy link

tthiery commented Jul 1, 2020

I am so glad you recognized this concept of pre-caching metadata on code level here. I also implemented it in SharpBrick.PoweredUp. Once you think about Port Value and CombinedMode decoding in a uniform way, the fact that protocol actually has state (combined mode) and needs knowledge (what are the data types, how many, ranges for raw, SI, PCT, etc) the need becomes obvious.

A hint regards hacking all the port information into the code. In my lib I ...

  1. trace a port discovery logic against a port id and dump the received messages in the output (independent exe basically)
  2. I create a new device class in code (naming it ... mostly stealing good names from here)
  3. Add the traced output into this class as a resource string
  4. My device initializer, then replays this output against my protocol stack (basically avoiding the length bluetooth based discovery) which then builds up its internal knowledge in the protocol.

While this may not work for devices not adhering to the protocol, it works quite nicely for the Technic ones I have ;). I think an adopted approach by dumping json from this tool instead of byte arrays is maybe the right thing here.

Using an external tool to capture the self-description messages can also help when you do not personally own a device (e.g. duplo train).

@tthiery
Copy link

tthiery commented Jul 1, 2020

Regards the POS (if you have not clarified this yet) of the motor ... POS is the amount of accumulated/moved degrees relative to initial value/position ... so it is not 360 to -360. It is the amount of degrees the motor has turned.

However, check this scaling code (and assume rawMin = min and rawMax = max) => the scaling result will be the same as the input value. So when Lego specs for "POS" Raw: -360 - 360 and SI -360 - 360 ... the effectively invalidate the scaling and any given raw value (e.g. int of any size) will just be passed through.

        internal static float Scale(float value, float rawMin, float rawMax, float min, float max)
        {
            var positionInRawRange = (value - rawMin) / (rawMax - rawMin);

            return (positionInRawRange * (max - min)) + min;
        }

As stated above, do not think rawMin and rawMax as the boundary of the communicated values. Think of them as the baseline for the si/pct related scaling.

@tthiery
Copy link

tthiery commented Jul 1, 2020

An architecture decision I made, was to put the Protocol in an independent object. This object is not only doing the byte[] <-> message object conversion but also holds the complete relevant knowledge and state (independent whether there is a device connected on the other side) which the decoder need. Like that I can have fun on top (doing e.g. a hub/device-like programming model or just doing some discovery logic without a hub like concept) and work with already decoded data. I see here a splitting of the decoding between hub and base type of device. I do not use hub or device base for that but have decided to host it in the protocol layer below.

You have a much more mature platform and have to deal with many more devices. So take this with a grain of salt.

@aileo
Copy link
Contributor Author

aileo commented Jul 4, 2020

  1. When using waitForDeviceByType after connect,, and the device is already plugged in at connection time, the promise is resolved, returning a device without any modes. Seems like this should wait for autoParsing to complete too?

I finally found why: it iterate over connected devices and returns the first one matching type regardless of its "ready" state. I will fix that.

@tthiery tthiery mentioned this pull request Jul 6, 2020
10 tasks
super.receive(message);
break;
}
this._eventHandlers.rotate = (data: IEventData) => {
Copy link
Owner

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Typo - this should be this._eventHandlers.absolute

raw: { min: 0, max: 512 },
pct: { min: 0, max: 100 },
si: { min: 0, max: 5120, symbol: "mm" },
values: { count: 1, type: Consts.ValueType.Int16 }
Copy link
Owner

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

This should be an Int8, also the raw/si values are incorrect for this sensor:

  lpf2hubmodeinfo Port 00, mode 0, name LPF2-DETECT +30ms
  lpf2hubmodeinfo Port 00, mode 0, RAW min 0, max 10 +30ms
  lpf2hubmodeinfo Port 00, mode 0, PCT min 0, max 100 +30ms
  lpf2hubmodeinfo Port 00, mode 0, SI min 0, max 10 +46ms
  lpf2hubmodeinfo Port 00, mode 0, SI symbol  +30ms
  lpf2hubmodeinfo Port 00, mode 0, Value 1 x 0, Decimal format

@nathankellenicki
Copy link
Owner

@aileo I spent a bit of time testing out the latest this evening, and for the most part, it works great. :) I made some smaller comments on a couple of typos and corrections that need made.

You might also be pleased to hear that WeDo 2.0 still works great. :) I tested the SPIKE Prime Large Angular Motor, the Boost Motor, and the WeDo 2.0 Distance and Tilt sensors, and they all work great with the WeDo 2.0 Smart hub as well as the Boost Move Hub, Powered UP Hub, and the Technic Control+ hub.

Where did you get most of the raw/pct/si values for the sensors/modes you implemented? When I get more time this week I plan on doing a more thorough test of all current sensor types with all hubs and all currently implemented modes (may take a wee while!), so I was thinking of double checking the mode definitions against those in this PR.

@aileo
Copy link
Contributor Author

aileo commented Aug 3, 2020

Where did you get most of the raw/pct/si values for the sensors/modes you implemented?

I used the lpf2hubmodeinfo messages for devices I have and guessed for the others

When I get more time this week I plan on doing a more thorough test of all current sensor types with all hubs and all currently implemented modes (may take a wee while!), so I was thinking of double checking the mode definitions against those in this PR.

That's why I started #100

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

Successfully merging this pull request may close these issues.

None yet

3 participants