A HomeKit Window Covering service.

Type Service Type
45 Window Covering

Window Covering was introduced in firmware version 0.9.0

The following configuration is available for window coverings:

Section Key Description
Actions "0", "1", etc. The actions performed by the service
Binary Inputs "b" GPIOs that invoke specific actions
Service Notifications "m" Notifications received from another service
Initial Lock State "ks" Lock state at boot
State & Status Inputs "f[n]" Inputs that manage service state
Actions on Boot "xa" Enable / Disable execution of service actions on boot
Wildcard Actions "y[n]" Perform an action when a service reaches a target value
Covering Type "w" Type of covering
Opening Time "o" Time for service to completely open
Closing Time "c" Time for service to completely close
Correction Value "f" Non-linear correction value for
Margin "m" Percentage margin to sync cover when fully open / close
Virtual Stop "vs" Simulates stop function from Home App
Data History Characteristics

Window Covering Example

{
  "c": {
    "io": [ [[4,15,0],2], [[2],6], [[5,13],6,0,1] ],
    "l": 0, "b": [ [2,5] ]
  },
  "a": [{
    "t": 45,
    "o": 18.3,
    "c": 14.8,
    "f": 40,
    "0": { "r": [ [15,1], [4] ] },
    "1": { "r": [ [15], [4,1] ] },
    "2": { "r": [ [15], [4] ] },
    "3": { "r": [ [15,0,0.2], [4] ] },
    "4": { "r": [ [15], [4,0,0.2] ] },
    "f0": [ [5,0] ],
    "f1": [ [13,0] ],
    "f2": [ [5], [13] ]
  }]
}

The above example defines a Shelly 2.5 Window Covering driver with external switches and a status LED "c": { "l": 0, "b": [ [2,5] ] }. The opening time is defined as 18.3 seconds "o": 18.3. The closing time is defined as 14.8 seconds "c": 14.8. A non-linear correction of 40% has also been set "f": 40.

Actions

A window covering has a number of actions as documented below:

Key Action Description
"0" Close, from stop Close the window covering from the stopped state
"1" Open, from stop Open the window covering from the stopped state
"2" Stop Stop the window covering opening or closing
"3" Close, from opening Action a close while window covering is opening
"4" Open, from closing Action an open while window covering is closing
"5" Stop, from closing Stop the window covering while it is closing
"6" Stop, from opening Stop the window covering while it is opening
"7" Obstruction removed
"8" Obstruction detected

The Binary Outputs "r": [ ] for each should be configured to attain the desired state.

Covering Type

The covering type is defined by the "w" key contained within the service object.

Key Value Description
"w" 0 Window covering (default) e.g. a roller blind
1 Window e.g. a motorized window
2 Door e.g. a motorized door

This option specifies the type of covering. Refer to the HomeKit specifications to see details on the differences between these device types.

Opening Time

Opening time is defined by the "o" key contained within the service object.

Key Value Description
"o" 15 Service opening time (default)
float Value specifying number of seconds

This option specifies the time the service takes to open completely. Decimals can be used.

Closing Time

Closing time is defined by the "c" key contained within the service object.

Key Value Description
"c" 15 Service closing time (default)
float Value specifying number of seconds

This option specifies the time the service takes to close completely. Decimals can be used.

Correction Value

Correction value is defined by the "f" key contained within the service object.

Key Value Description
"f" 0 Non-linear correction value (_default)
0 to 100 Percentage value

Some window coverings may require a correction factor to determine their real position with respect to open or closing state. This may be due to the it being a roller shutter for instance. Where the amount the covering opens accelerates as it opens due to the drum of the shutter.

You can modify how the position of the shutter is calculated by providing a non-linear correction value.

When a correction value is provided the position of the service is calculated as follows:

HomeKit Position = motorPosition / (1 + ((100 - motorPosition) * correctionValue * 0.0002))

This option specifies a percentage. It is an integer between 0 and 100.

How to find the right correction value?

It is a trial and error procedure:

  • Close window cover.
  • Open it at 50% in Apple Home.
    • If real window cover position is under 50%, use a higher correction "f": value.
    • If real window cover position is above 50%, use a lower correction "f": value.
  • Remember to close window cover before enter setup to change the correction value.

Margin

Margin is defined by the "m" key contained within the service object.

Key Value Description
"m" 5 Percentage margin (default)
0 to 100 Integer value specifying percentage

This option specifies the additional working time used by the AI algorithm when a cover is set to fully open or fully closed to help recalibrating its position. For example, if opening working time is 18 seconds, and margin is 10% (meaning 10% of 18s = 1.8s), when cover is set to fully open, stop action will exec after 1.8s cover is fully open to ensure that it is at target position.

This extra time must not be used into normal working time. When margin is used, opening and closing times must be right and precises, not shorter.

It is an integer (no decimals) specifying the percentage.

Virtual Stop

When enabled, it simulates stop function from Home App when window covering is moving and service is triggered again from Apple Home App, instead changing movement direction.

Key Value Description
"vs" 0 Virtual Stop disabled (default)
1 Virtual Stop enabled

Service Notifications

The list of notifications "m" supported by a window covering are as follows:

Value Notification
-3 Toggle current window covering mode between open/stop/close
-2 Obstruction removed
-1 Obstruction detected
0 to 100 Set window covering to specified open percentage
101 It will stop the window covering opening or closing
200 to 300 Set window covering state only to specified open percentage - 200

See the general Service Notifications section for details of how to configure these notifications.

Binary Inputs

Binary Inputs "b" are supported by this service.

See Binary Inputs for details on how to define this mandatory option.

State and Status Inputs

State inputs "f[n]" are supported by this service. The supported list is:

Key Required State
"f0" Close window covering
"f1" Open window covering
"f2" Stop window covering opening or closing
"f3" Toggle between closing and stop
"f4" Toggle between opening and stop
"f5" Indicates that there is no obstruction
"f6" Indicates that there is an obstruction
"f7" Toggle current window covering mode between open/stop/close

Refer to State Inputs for more detail and examples.

Initial Lock State

The Initial Lock State about Service and Physical controls.

Key Value Notification
"ks" 0 All locked
1 Service unlocked. Physical controls locked
2 Service locked. Physical controls unlocked
3 All unlocked (default)

Execution of Actions on Boot

Actions on Boot "xa" are supported by this service.

See Execution of Actions on Boot for details on how to define this mandatory option.

Wildcard Actions

Wildcard Actions "y[n]" are supported by this service. The supported list is:

Key Action
"y0" Trigger action when service reaches a specific position

The position of the window covering is expressed as a percentage e.g. {"y0":[{"v": 20, "0"{...}}]}

Refer to Wildcard Actions for more detail.

Data History Characteristics

Characteristic Description
0 Current position
1 Target position
2 Position state
3  Obstruction detected