EEMBackplane
Note that presently there is no officially supported EEM backplane (only the EEM Connectors). It has been discussed several times though. Following is a summary of a proposed backplane.
- Backplane design discussion, issue #129
- Second backplane discussion, issue #168
- Discussion of putting active electronics on EEM backplane, issue #233
The 96 position DIN 41612 connector from Kasli should be used to supply backplane-compatible EEMs or a breakout board for more EEM connectors. Supporting the backplane from an EEM is optional. Depending on electrical simplicity an EEM could opt to support an EEM Connector interface and backplane signaling as a runtime alternative, or as a fixed design choice.
The equivalent of four EEMs is supplied from Kasli through the backplane. Whether these four backplane EEMs are in addition to the eight EEM Connectors s or mutually exclusive with them remains TBD. The backplane is passive.
- 1 pin: 3.3 V management power
- 2 pins: 12 V
- 3 pins: GND
- 4x2 (1 pair per EEM): provide a reference clock signal to EEMs
- 4x2 (2 per EEM): I2C
- 4x2x8 (8 LVDS pairs per EEM)
- 10 pins remaining for more power/GND
The signals are star-routed to several EEM DIN 41612 connectors in a barrel-shifted way so that a single EEM can claim up to four EEM links. The EEM connector pinout should be the same as Kasli. The four CLK/I2C/LVDS groups should be assigned in two different ways.
If the unused LVDS and clock stubs are not a problem, the backplane layout could be a very flexible routing (where 4-link EEMs can be plugged into any slot) or a more fixed routing (but with no stub problems).
- 0: 0, 1, 2, 3 (Kasli)
- 1: 0, 1, 2, 3 (up to quad-link EEM)
- 2: 1, 2, 3 (up to triple-link EEM)
- 3: 2, 3 (up to double-link EEM)
- 4: 3 (single-link EEM)
The EEM pitch should such that a 19 inch subrack can be filled. Then if e.g. a single-link EEM is pliugged into slot 1, it will claim only link 1 and all slots to the right (2-4) can be used. A double-link EEM plugged into slot 3 would claim links 2 and 3 and slot 4 can not be used. An N-link EEM requires that the N-1 slots to the right of it are empty.
- 0: 0, 1, 2, 3
- 1: 1, 2, 3, 0
- 2: 2, 3, 0, 1
- 3: 3, 0, 1, 2
- 4: 0, 1, 2, 3
- 5: 1, 2, 3, 0
- 6: 2, 3, 0, 1
- etc.
The pitch between connectors on the backplane can e.g. be 4 HP. If e.g. Kasli is plugged into slot 0, it drives all four groups from there. Then if e.g. a single-link EEM is pliugged into slot 1, it will claim only link 1. A double-link EEM plugged into slot 6 would claim links 2 and 3. An N-link EEM requires that the N-1 slots to the right of it are empty.
To clean up the wiring in the rack, one could design a simple mezzanine for Kasli (or the VHDCI carrier) that plugs into its EEM Connectors (four or 8) and then routes them through another (or two) DIN connectors to the backplane. The backplane would then do all the wiring for EEMs significantly reducing the ribbon rats nest.
Home
Team
Project Status
Purchasing Hardware
Style Guide
Kasli: FPGA Carrier
Kasli-SOC: SoC FPGA Carrier
DIO_BNC: Digital IO on BNCs
DIO_SMA: Digital IO on SMAs
DIO_MCX: Digital IO on MCXs
DIO_RJ45: LVDS IO on RJ45s
Zotino: 32ch DAC
Fastino: 32ch DAC
Zapper: 8ch Piezo Driver
HV_AMP_8CH: 8ch High Voltage Amp
Sampler: 8ch ADC
Mirny: Microwave Synthesiser
Almazny: 12GHz Mirny Mezzanine
Urukul: 4ch DDS
Phaser: 2ch AWG
Stabilizer: 2xADC+2xDAC Servo
Pounder: Stabilizer PDH Lock
Thermostat_EEM: 4ch Temp Controller
Kirdy: laser current driver
Clocker: Clock Buffer
AUX_PSU: 3-ch PSU
EEM_PWR_MOD_AC: Mains PSU
Humpback: SBC Carrier
VHDCI Carrier: VHDCI to EEM
Grabber: Camera Frame Grabber
Banker: Versatile 128x IO
uTCA Chassis
Metlino: uTCA MCH
Sayma: 8-channel smart AWG
RFSOC-AMC: RFSoC Platform
Clock generation mezzanines
Sayma analogue front ends
Misc uTCA hardware
Shuttler: 16ch fast DAC
TDC+ADC: 16ch
Booster: 8ch RF Power Amplifier
DiPho: Digital Photodiode
Thermostat: 2ch Temp Controller
Line Trigger
IDC-BNC
IDC-SMA
HD68 to IDC
Kasli BP Adapter
MCX_BNC_adapter
SATA to SFP
EDGE-SMA
EDGE-BNC
EDGE-SUBD9
EDGE-VHDCI
EDGE-VHDCI-buf
SFP: recommended components