Sigfox RF and PROTOCOL Test Report

Unabiz
Product Type : Device
Commercial Name : Low Cost Reference Design Holtek
Model Name : LCD-Holtek
Configuration : RC1-UL
Modem : v4.0.0
Firmware : v1.0.rfp
Sigfox lib/Addon : v3.3

Name Date
Author Unabiz 2023-10-19
Review Unabiz
Maximum Voltage Modulated Output Power measured: 13.8dBm
Link Budget: ✅NOT_APPLICABLE

1 Introduction

This document shows the results of the RF product qualification for Sigfox RF & PROTOCOL Specification Compliance.

2 Test Setup

2.1 Device Test Setup Configuration

Device test setup configuration :

Parameter Value
Nominal Voltage +3.0V
Minimum Voltage +2.0V
Maximum Voltage +3.6V
Carrier Sense

2.2 Device Configuration settings in RSA

Parameter Value
Device ID : ID[0] = 0x98 ... ID[3] = 0xFE FEDCBA98
Device Private Key : key[0] = 0x01 ... key[15] = 0xEF 0123456789ABCDEF0123456789ABCDEF
Radio Configuration RC1
RC3 Spectrum Access NO SELECTED VALUE
RC Baudrate (bps) 100
Message Counter Maximum Value 4096
Downlink capable NOT_SUPPORTED
Monarch Capable NOT_SUPPORTED
Public Key switch capable NOT_SUPPORTED
Payload Encryption Configuration No Payload Encryption
Payload Encryption Rollover Counter value 0
Multi Frame Capable SUPPORTED
All Message Types Supported NOT_SUPPORTED
Frame Type No Payload SUPPORTED
Frame Type Bit (False) SUPPORTED
Frame Type Bit (True) SUPPORTED
Keep Alive Frame Type NOT_SUPPORTED
1 Byte Frame Type SUPPORTED
2 Bytes Frame Type SUPPORTED
3 Bytes Frame Type SUPPORTED
4 Bytes Frame Type SUPPORTED
5 Bytes Frame Type SUPPORTED
6 Bytes Frame Type SUPPORTED
7 Bytes Frame Type SUPPORTED
8 Bytes Frame Type SUPPORTED
9 Bytes Frame Type SUPPORTED
10 Bytes Frame Type SUPPORTED
11 Bytes Frame Type SUPPORTED
12 Bytes Frame Type SUPPORTED
Oscillator Aging for 5 years (ppm) 3
Oscillator Temperature Accuracy (ppm) 7
Product's Population Frequency Accuracy(ppm) 10
Minimum Voltage = Nominal Voltage NOT_SUPPORTED
Maximum Voltage = Nominal Voltage NOT_SUPPORTED

2.3 Equipments

The qualification is performed using following Laboratory instrumentation :

Setup Equipment
TX Test Setup - DBPSK Modulation Quality A
TX Test Setup - Demodulated Information A
TX/RX Test Setup NA
RX Test Setup NA
TX Test Setup - LBT NA
Monarch Test Setup NA

2.4 Laboratory Instrumentation

No. Equipment Manufacturer Serial Number
A FSV7 Rohde&Schwarz

2.5 Firmware

No. Firmware Manufacturer Version
1 Radio Signal Analyzer Sigfox 3.2.0

3 Sigfox RF & Protocol Specification version

Version
Sigfox RF & Protocol Specification 5.1.0

4 Test Environment

Sensitivity Uncertainty +/- 1 dB
Temperature Uncertainty +/- 2 °C
Power Measurement Uncertainty +/- 1 dB
Temperature 25 °C

5 Sigfox RF & Protocol

All tests are sanctioned by following information:

Verdict Info
✖️NOT_TESTED The test has not been executed
✔️PASS The test has been properly executed and match with the Sigfox specification
❌FAIL The test has not been properly executed and/or does not match with the Sigfox specification
🆗INFO Measurement has been done but it's not a verdict

6 Operational Requirements Results

[PRS-RFP-001] : Spectral Occupation Products Population :

Test Result Vnom Voltage: ✔️PASS

Modulation Type Frame Rep bit Freq Rssi Start Stop Length Id Msg C Dlk Data hmac crc
PSK Data 1 No 10679 13.60 28.239 29.359 1.120 FEDCBA98 310 No - OK OK
PSK Data 1 No 10800 13.48 38.422 39.542 1.120 FEDCBA98 311 No - OK OK
PSK Data 1 No 10859 13.52 48.545 49.665 1.120 FEDCBA98 312 No - OK OK
PSK Data 1 No 10979 13.52 58.728 59.848 1.120 FEDCBA98 313 No - OK OK
PSK Data 1 No 11103 13.48 68.925 70.045 1.120 FEDCBA98 314 No - OK OK
PSK Data 1 No 11165 13.52 79.108 80.228 1.120 FEDCBA98 315 No - OK OK
PSK Data 1 No 11287 13.48 89.281 90.401 1.120 FEDCBA98 316 No - OK OK
PSK Data 1 No 11350 13.52 99.464 100.584 1.120 FEDCBA98 317 No - OK OK
PSK Data 1 No 11470 13.60 109.646 110.766 1.120 FEDCBA98 318 No - OK OK

Number of received frames : 9
Maximum step frequency error : 124 Hz

[PRS-RFP-002] : Operational Frequencies Range :

Test Result Vnom Voltage: ✔️PASS

Number of received frames : 300
Frequency range : 153582 Hz

[PRS-RFP-003] : Operational Frequencies Distribution :

Test Result Vnom Voltage: ✔️PASS
Number of received frames : 300

[PRS-RFP-004] : Static Frequency Tolerance :

Test Result Vnom Voltage: ✔️PASS
Max Measured Static frequency Drift (in ppm) : 0.737217 ppm
Max Measured Static frequency Drift (in ppm) with aging and temperature : 10.7372 ppm
Declared Aging for 5 years : 3.00 ppm - Declared Temperature Accuracy: 7.00 ppm - Product's Population Frequency Accuracy Declared: 10.00 ppm -

Test Result Vmin Voltage: ✔️PASS
Max Measured Static frequency Drift (in ppm) : 1.04477 ppm
Max Measured Static frequency Drift (in ppm) with aging and temperature : 11.0448 ppm
Declared Aging for 5 years : 3.00 ppm - Declared Temperature Accuracy: 7.00 ppm - Product's Population Frequency Accuracy Declared: 10.00 ppm -

Test Result Vmax Voltage: ✔️PASS
Max Measured Static frequency Drift (in ppm) : 0.744128 ppm
Max Measured Static frequency Drift (in ppm) with aging and temperature : 10.7441 ppm
Declared Aging for 5 years : 3.00 ppm - Declared Temperature Accuracy: 7.00 ppm - Product's Population Frequency Accuracy Declared: 10.00 ppm -

[PRS-RFP-010] : DBPSK Modulation :

Test Result Vnom Voltage: ✔️PASS

Modulation Type Frame Rep bit Freq Rssi Start Stop Length Id Msg C Dlk Data hmac crc
PSK Data 1 No 10640 13.82 18.197 20.277 2.080 FEDCBA98 4 No AAAAAAAAAAAAAAAAAAAAAAAA OK OK
PSK Data 1 No 10625 13.76 20.431 22.511 2.080 FEDCBA98 5 No AAAAAAAAAAAAAAAAAAAAAAAA OK OK
PSK Data 1 No 10621 13.78 22.666 24.746 2.080 FEDCBA98 6 No AAAAAAAAAAAAAAAAAAAAAAAA OK OK

Test Result Vmin Voltage: ✔️PASS

Modulation Type Frame Rep bit Freq Rssi Start Stop Length Id Msg C Dlk Data hmac crc
PSK Data 1 No 10907 11.89 19.155 21.235 2.080 FEDCBA98 7 No AAAAAAAAAAAAAAAAAAAAAAAA OK OK
PSK Data 1 No 10902 11.92 21.390 23.470 2.080 FEDCBA98 8 No AAAAAAAAAAAAAAAAAAAAAAAA OK OK
PSK Data 1 No 10899 11.90 23.625 25.705 2.080 FEDCBA98 9 No AAAAAAAAAAAAAAAAAAAAAAAA OK OK

Test Result Vmax Voltage: ✔️PASS

Modulation Type Frame Rep bit Freq Rssi Start Stop Length Id Msg C Dlk Data hmac crc
PSK Data 1 No 10646 14.21 285.785 287.865 2.080 FEDCBA98 1 No AAAAAAAAAAAAAAAAAAAAAAAA OK OK
PSK Data 1 No 10628 14.25 288.019 290.099 2.080 FEDCBA98 2 No AAAAAAAAAAAAAAAAAAAAAAAA OK OK
PSK Data 1 No 10624 14.26 290.254 292.334 2.080 FEDCBA98 3 No AAAAAAAAAAAAAAAAAAAAAAAA OK OK

[PRS-RFP-011] : Phase Measurement :

Test Result Vnom Voltage: ✔️PASS

RMS : 1.41049 $^{\circ}$
Peak : -7.19319 $^{\circ}$

Test Result Vmin Voltage: ✔️PASS

RMS : 1.40554 $^{\circ}$
Peak : 8.28741 $^{\circ}$

Test Result Vmax Voltage: ✔️PASS

RMS : 1.40366 $^{\circ}$
Peak : -7.85636 $^{\circ}$

[PRS-RFP-012] : Extra Symbols Before The First Sigfox Bit Of The Frame :

Test Result Vnom Voltage: ✔️PASS

Measured extra symbol : 1.00677 symbols

Test Result Vmin Voltage: ✔️PASS

Measured extra symbol : 1.00729 symbols

Test Result Vmax Voltage: ✔️PASS

Measured extra symbol : 1.00677 symbols

[PRS-RFP-013] : Extra Symbols After The Last Sigfox Bit Of The Frame :

Test Result Vnom Voltage: ✔️PASS

Measured extra symbol : 0.877083 symbols

Test Result Vmin Voltage: ✔️PASS

Measured extra symbol : 0.883333 symbols

Test Result Vmax Voltage: ✔️PASS

Measured extra symbol : 0.876563 symbols

[PRS-RFP-014] : TX Max Symbol Duration :

Test Result Vnom Voltage: ✔️PASS

Maximum error : 0.0521105 %

Test Result Vmin Voltage: ✔️PASS

Maximum error : 0.0521105 %

Test Result Vmax Voltage: ✔️PASS

Maximum error : 0.0521105 %

[PRS-RFP-015] : Max TX Baudrate Cumulated Error :

Test Result Vnom Voltage: ✔️PASS

Maximum error : 0.000544116 %

Test Result Vmin Voltage: ✔️PASS

Maximum error : -0.000259473 %

Test Result Vmax Voltage: ✔️PASS

Maximum error : -0.00025531 %

[PRS-RFP-016] : Power Spectral Density For Class 0 And 1 :

Test Result Vnom Voltage: ✔️PASS

Test Result Vmin Voltage: ✔️PASS

Test Result Vmax Voltage: ✔️PASS

[PRS-RFP-017] : Power Spectral Density For Class 2 And 3 :

Test Result Vnom Voltage: ✔️PASS

Test Result Vmin Voltage: ✔️PASS

Test Result Vmax Voltage: ✔️PASS

[PRS-RFP-018] : Transitional Frequency Dynamic Drift :

Test Result Vnom Voltage: ✔️PASS

Maximum measured drift : -7.97428 Hz/s

Test Result Vmin Voltage: ✔️PASS

Maximum measured drift : -5.79157 Hz/s

Test Result Vmax Voltage: ✔️PASS

Maximum measured drift : -9.05231 Hz/s

[PRS-RFP-019] : Established Frequency Dynamic Drift :

Test Result Vnom Voltage: ✔️PASS

Maximum measured drift : -10.8337 Hz/s

Test Result Vmin Voltage: ✔️PASS

Maximum measured drift : -7.754 Hz/s

Test Result Vmax Voltage: ✔️PASS

Maximum measured drift : -14.6583 Hz/s

[PRS-RFP-020] : GFSK 600bps :

Test Result Vnom Voltage: ✅NOT_APPLICABLE

[PRS-RFP-021] : Sigfox Link Budget :

Test Result Vnom Voltage: ✅NOT_APPLICABLE

[PRS-RFP-030] : AES :

Test Result Vnom Voltage: ✔️PASS

[PRS-RFP-031] : Frequency Storage :

Test Result Vnom Voltage: ✔️PASS
: 9

[PRS-RFP-032] : Message Counter Storage :

Test Result Vnom Voltage: ✔️PASS

Modulation Type Frame Rep bit Freq Rssi Start Stop Length Id Msg C Dlk Data hmac crc
PSK Data 1 No -4765 13.60 6.024 7.144 1.120 FEDCBA98 334 No - OK OK
PSK Data 2 No -45851 13.53 7.681 8.801 1.120 FEDCBA98 334 No - OK OK
PSK Data 3 No 75484 13.41 9.337 10.457 1.120 FEDCBA98 334 No - OK OK
PSK Data 1 No 64389 13.59 29.107 30.227 1.120 FEDCBA98 335 No - OK OK
PSK Data 2 No 4197 13.52 30.764 31.884 1.120 FEDCBA98 335 No - OK OK
PSK Data 3 No 40570 13.46 32.420 33.540 1.120 FEDCBA98 335 No - OK OK
PSK Data 1 No -60614 13.47 52.137 53.257 1.120 FEDCBA98 336 No - OK OK
PSK Data 2 No -51043 13.48 53.793 54.913 1.120 FEDCBA98 336 No - OK OK
PSK Data 3 No 68158 13.33 55.450 56.570 1.120 FEDCBA98 336 No - OK OK

[PRS-RFP-033] : Public Key Switch :

Test Result Vnom Voltage: ✅NOT_APPLICABLE

[PRS-RFP-034] : Number Of Frames Per Message In Single Frame Uplink Mode :

Test Result Vnom Voltage: ✅NOT_APPLICABLE

[PRS-RFP-034] : Number Of Frames Per Message In Multi Frames Uplink Mode :

Test Result Vnom Voltage: ✔️PASS

[PRS-RFP-035] : Legacy Uplink :

Test Result Vnom Voltage: ✔️PASS

Modulation Type Frame Rep bit Freq Rssi Start Stop Length Id Msg C Dlk Data hmac crc
PSK Data 1 No 2684 13.67 8.334 9.454 1.120 FEDCBA98 319 No - OK OK
PSK Data 2 No -52010 13.47 9.991 11.111 1.120 FEDCBA98 319 No - OK OK
PSK Data 3 No 6578 13.29 11.648 12.768 1.120 FEDCBA98 319 No - OK OK
PSK Bit 1 No 31557 13.56 30.805 31.925 1.120 FEDCBA98 320 No BitState=False OK OK
PSK Bit 2 No 10369 13.49 32.462 33.582 1.120 FEDCBA98 320 No BitState=False OK OK
PSK Bit 3 No -48471 13.41 34.119 35.239 1.120 FEDCBA98 320 No BitState=False OK OK
PSK Bit 1 No 70680 13.56 53.330 54.450 1.120 FEDCBA98 321 No BitState=True OK OK
PSK Bit 2 No -76178 13.51 54.987 56.107 1.120 FEDCBA98 321 No BitState=True OK OK
PSK Bit 3 No -74289 13.50 56.644 57.764 1.120 FEDCBA98 321 No BitState=True OK OK
PSK Data 1 No 39003 13.44 75.859 77.059 1.200 FEDCBA98 322 No 40 OK OK
PSK Data 2 No -1043 13.50 77.596 78.796 1.200 FEDCBA98 322 No 40 OK OK
PSK Data 3 No 30265 13.42 79.334 80.534 1.200 FEDCBA98 322 No 40 OK OK
PSK Data 1 No -67807 13.46 98.607 100.047 1.440 FEDCBA98 323 No 4041 OK OK
PSK Data 2 No -31015 13.50 100.585 102.025 1.440 FEDCBA98 323 No 4041 OK OK
PSK Data 3 No 52234 13.51 102.564 104.004 1.440 FEDCBA98 323 No 4041 OK OK
PSK Data 1 No 32413 13.52 122.096 123.536 1.440 FEDCBA98 324 No 404142 OK OK
PSK Data 2 No 58707 13.63 124.074 125.514 1.440 FEDCBA98 324 No 404142 OK OK
PSK Data 3 No -36511 13.54 126.053 127.493 1.440 FEDCBA98 324 No 404142 OK OK
PSK Data 1 No 27592 13.40 145.584 147.024 1.440 FEDCBA98 325 No 40414243 OK OK
PSK Data 2 No 74884 13.53 147.562 149.002 1.440 FEDCBA98 325 No 40414243 OK OK
PSK Data 3 No 25258 13.43 149.541 150.981 1.440 FEDCBA98 325 No 40414243 OK OK
PSK Data 1 No -64327 13.33 169.059 170.819 1.760 FEDCBA98 326 No 4041424344 OK OK
PSK Data 2 No 31302 13.66 171.359 173.119 1.760 FEDCBA98 326 No 4041424344 OK OK
PSK Data 3 No -6360 13.46 173.659 175.419 1.760 FEDCBA98 326 No 4041424344 OK OK
PSK Data 1 No 15446 13.41 193.523 195.283 1.760 FEDCBA98 327 No 404142434445 OK OK
PSK Data 2 No -46824 13.64 195.823 197.583 1.760 FEDCBA98 327 No 404142434445 OK OK
PSK Data 3 No 15124 13.44 198.123 199.883 1.760 FEDCBA98 327 No 404142434445 OK OK
PSK Data 1 No -66342 13.36 217.980 219.740 1.760 FEDCBA98 328 No 40414243444546 OK OK
PSK Data 2 No 58097 13.61 220.281 222.041 1.760 FEDCBA98 328 No 40414243444546 OK OK
PSK Data 3 No -70997 13.54 222.581 224.341 1.760 FEDCBA98 328 No 40414243444546 OK OK
PSK Data 1 No -69212 13.36 242.414 244.174 1.760 FEDCBA98 329 No 4041424344454647 OK OK
PSK Data 2 No 39480 13.63 244.714 246.474 1.760 FEDCBA98 329 No 4041424344454647 OK OK
PSK Data 3 No 27758 13.56 247.015 248.775 1.760 FEDCBA98 329 No 4041424344454647 OK OK
PSK Data 1 No -69214 13.46 266.879 268.959 2.080 FEDCBA98 330 No 404142434445464748 OK OK
PSK Data 2 No 38929 13.65 269.501 271.581 2.080 FEDCBA98 330 No 404142434445464748 OK OK
PSK Data 3 No -7342 13.53 272.122 274.202 2.080 FEDCBA98 330 No 404142434445464748 OK OK
PSK Data 1 No -46635 13.39 292.269 294.349 2.080 FEDCBA98 331 No 40414243444546474849 OK OK
PSK Data 2 No 26046 13.62 294.891 296.971 2.080 FEDCBA98 331 No 40414243444546474849 OK OK
PSK Data 3 No -17719 13.53 297.512 299.592 2.080 FEDCBA98 331 No 40414243444546474849 OK OK
PSK Data 1 No -61951 13.33 317.704 319.784 2.080 FEDCBA98 332 No 404142434445464748494A OK OK
PSK Data 2 No 18297 13.70 320.335 322.415 2.080 FEDCBA98 332 No 404142434445464748494A OK OK
PSK Data 3 No -26508 13.46 322.966 325.046 2.080 FEDCBA98 332 No 404142434445464748494A OK OK
PSK Data 1 No 21666 13.40 343.151 345.231 2.080 FEDCBA98 333 No 404142434445464748494A4B OK OK
PSK Data 2 No 20373 13.63 345.782 347.862 2.080 FEDCBA98 333 No 404142434445464748494A4B OK OK
PSK Data 3 No -57268 13.56 348.413 350.493 2.080 FEDCBA98 333 No 404142434445464748494A4B OK OK

Number of expected frames : 45
Number of received frames : 45

[PRS-RFP-036] : Uplink Encrypted Payload :

Test Result Vnom Voltage: ✅NOT_APPLICABLE

[PRS-RFP-037] : Downlink Legacy :

Test Result Vnom Voltage: ✅NOT_APPLICABLE

[PRS-RFP-038] : Downlink Encrypted Payload :

Test Result Vnom Voltage: ✅NOT_APPLICABLE

[PRS-RFP-040] : Number Of Uplink Frame In Single Frame Bidirectional Mode :

Test Result Vnom Voltage: ✅NOT_APPLICABLE

[PRS-RFP-040] : Number Of Uplink Frame In Multi Frames Bidirectional Mode :

Test Result Vnom Voltage: ✅NOT_APPLICABLE

[PRS-RFP-041] : Carrier Center Frequencies In Bidirectional Mode :

Test Result Vnom Voltage: ✅NOT_APPLICABLE

[PRS-RFP-050] : TX Interframe Timing In Uplink Mode :

Test Result Vnom Voltage: ✔️PASS
Minimum measured interframe : 0.536734 s
Maximum measured interframe : 0.551094 s

[PRS-RFP-051] : TX Repeat Iimeout :

Test Result Vnom Voltage: ✅NOT_APPLICABLE

[PRS-RFP-052] : TX Interframe Timing In Bidirectional Mode :

Test Result Vnom Voltage: ✅NOT_APPLICABLE

[PRS-RFP-053] : RX Start Of Listening :

Test Result Vnom Voltage: ✅NOT_APPLICABLE

[PRS-RFP-054] : RX End Of Listening :

Test Result Vnom Voltage: ✅NOT_APPLICABLE

[PRS-RFP-055] : RX To Confirmation Control Message Timing :

Test Result Vnom Voltage: ✅NOT_APPLICABLE

[PRS-RFP-060] : RC Determination From Monarch Signal At High Power Level :

Test Result Vnom Voltage: ✅NOT_APPLICABLE

[PRS-RFP-061] : Link Budget On Monarch Signal :

Test Result Vnom Voltage: ✅NOT_APPLICABLE

[PRS-RFP-062] : Robustness To High Power Level Interferer For Monarch Signal :

Test Result Vnom Voltage: ✅NOT_APPLICABLE

[PRS-RFP-063] : Robustness To Low Power Level Interferer For Monarch Signal :

Test Result Vnom Voltage: ✅NOT_APPLICABLE

[PRS-RFP-070] : Modulated Conducted Output Power :

Test Result Vnom Voltage: 🆗INFO
Minimum Measured output power : 13.764 dBm
Maximum Measured output power : 13.8232 dBm

Test Result Vmin Voltage: 🆗INFO
Minimum Measured output power : 11.893 dBm
Maximum Measured output power : 11.923 dBm

Test Result Vmax Voltage: 🆗INFO
Minimum Measured output power : 14.2107 dBm
Maximum Measured output power : 14.258 dBm

[PRS-RFP-071] : UUT Temperature Level :

Test Result Vnom Voltage: ✅NOT_APPLICABLE

[PRS-RFP-072] : UUT Voltage Level :

Test Result Vnom Voltage: ✅NOT_APPLICABLE

[PRS-RFP-073] : IQ Wave Record :

Test Result Vnom Voltage: ✔️PASS

7 Tracability Matrix

Ref Requirement Voltage Verdict
[PRS-RFP-001] Spectral Occupation Products Population Vnom
✔️PASS
[PRS-RFP-002] Operational Frequencies Range Vnom
✔️PASS
[PRS-RFP-003] Operational Frequencies Distribution Vnom
✔️PASS
[PRS-RFP-004] Static Frequency Tolerance Vnom
Vmin
Vmax
✔️PASS
✔️PASS
✔️PASS
[PRS-RFP-010] DBPSK Modulation Vnom
Vmin
Vmax
✔️PASS
✔️PASS
✔️PASS
[PRS-RFP-011] Phase Measurement Vnom
Vmin
Vmax
✔️PASS
✔️PASS
✔️PASS
[PRS-RFP-012] Extra Symbols Before The First Sigfox Bit Of The Frame Vnom
Vmin
Vmax
✔️PASS
✔️PASS
✔️PASS
[PRS-RFP-013] Extra Symbols After The Last Sigfox Bit Of The Frame Vnom
Vmin
Vmax
✔️PASS
✔️PASS
✔️PASS
[PRS-RFP-014] TX Max Symbol Duration Vnom
Vmin
Vmax
✔️PASS
✔️PASS
✔️PASS
[PRS-RFP-015] Max TX Baudrate Cumulated Error Vnom
Vmin
Vmax
✔️PASS
✔️PASS
✔️PASS
[PRS-RFP-016] Power Spectral Density For Class 0 And 1 Vnom
Vmin
Vmax
✔️PASS
✔️PASS
✔️PASS
[PRS-RFP-017] Power Spectral Density For Class 2 And 3 Vnom
Vmin
Vmax
✔️PASS
✔️PASS
✔️PASS
[PRS-RFP-018] Transitional Frequency Dynamic Drift Vnom
Vmin
Vmax
✔️PASS
✔️PASS
✔️PASS
[PRS-RFP-019] Established Frequency Dynamic Drift Vnom
Vmin
Vmax
✔️PASS
✔️PASS
✔️PASS
[PRS-RFP-020] GFSK 600bps Vnom
✅NOT_APPLICABLE
[PRS-RFP-021] Sigfox Link Budget Vnom
✅NOT_APPLICABLE
[PRS-RFP-030] AES Vnom
✔️PASS
[PRS-RFP-031] Frequency Storage Vnom
✔️PASS
[PRS-RFP-032] Message Counter Storage Vnom
✔️PASS
[PRS-RFP-033] Public Key Switch Vnom
✅NOT_APPLICABLE
[PRS-RFP-034] Number Of Frames Per Message In Single Frame Uplink Mode Vnom
✅NOT_APPLICABLE
[PRS-RFP-034] Number Of Frames Per Message In Multi Frames Uplink Mode Vnom
✔️PASS
[PRS-RFP-035] Legacy Uplink Vnom
✔️PASS
[PRS-RFP-036] Uplink Encrypted Payload Vnom
✅NOT_APPLICABLE
[PRS-RFP-037] Downlink Legacy Vnom
✅NOT_APPLICABLE
[PRS-RFP-038] Downlink Encrypted Payload Vnom
✅NOT_APPLICABLE
[PRS-RFP-040] Number Of Uplink Frame In Single Frame Bidirectional Mode Vnom
✅NOT_APPLICABLE
[PRS-RFP-040] Number Of Uplink Frame In Multi Frames Bidirectional Mode Vnom
✅NOT_APPLICABLE
[PRS-RFP-041] Carrier Center Frequencies In Bidirectional Mode Vnom
✅NOT_APPLICABLE
[PRS-RFP-050] TX Interframe Timing In Uplink Mode Vnom
✔️PASS
[PRS-RFP-051] TX Repeat Iimeout Vnom
✅NOT_APPLICABLE
[PRS-RFP-052] TX Interframe Timing In Bidirectional Mode Vnom
✅NOT_APPLICABLE
[PRS-RFP-053] RX Start Of Listening Vnom
✅NOT_APPLICABLE
[PRS-RFP-054] RX End Of Listening Vnom
✅NOT_APPLICABLE
[PRS-RFP-055] RX To Confirmation Control Message Timing Vnom
✅NOT_APPLICABLE
[PRS-RFP-060] RC Determination From Monarch Signal At High Power Level Vnom
✅NOT_APPLICABLE
[PRS-RFP-061] Link Budget On Monarch Signal Vnom
✅NOT_APPLICABLE
[PRS-RFP-062] Robustness To High Power Level Interferer For Monarch Signal Vnom
✅NOT_APPLICABLE
[PRS-RFP-063] Robustness To Low Power Level Interferer For Monarch Signal Vnom
✅NOT_APPLICABLE
[PRS-RFP-070] Modulated Conducted Output Power Vnom
Vmin
Vmax
🆗INFO
🆗INFO
🆗INFO
[PRS-RFP-071] UUT Temperature Level Vnom
✅NOT_APPLICABLE
[PRS-RFP-072] UUT Voltage Level Vnom
✅NOT_APPLICABLE
[PRS-RFP-073] IQ Wave Record Vnom
✔️PASS